1) The shearer is shielded with a rubber sheathed flexible cable, the working voltage is 0.66/1.14KV, the power core is 3*50, the grounding core is 1*10, the control core is 4*4, with a semi-conductive shielding layer, The representative is: MCP-0.66/1.143*50+1*10+4*4MT818.2-1999


2) The shearer is shielded and braided into a reinforced rubber sheathed flexible cable with a working voltage of 0.66/1.14KV, a power core of 3*50, a ground core of 1*25, and a control core of 2*2.5, with semi-conductive Shielded layer, monitoring wire core and braided reinforcement layer, representative: MCPJB-0.66/1.143*50+1*25+2*2.5MT818.3-1999

3) Shearer metal shielded monitoring type rubber sheathed flexible cable, working voltage 0.66/1.14KV, power core 3*70, grounding core 1*25, monitoring core 1*35, with metal shielding layer, representing for MCPTJ-0.66/1.143*70+1*35+1*35MT818.4-1999


4) Removable elastomer flexible cable for coal mining industry, working voltage 0.38/0.66KV, power core 3*25, grounding core 1*16, without shielding layer, representative: MYE-0.38/0.663*25+ 1*16MT818.5-1999


5) Removable metal shielded monitoring rubber sheathed flexible cable for coal mining industry, working voltage 3.6/6KV, power core 3*35, grounding core 3*16/3, monitoring core 3*2.5, with semi-conductive shielding layer, the representative is: MYPTJ-3.6/63*35+3*16/3+3*2.5MT818.6-1999


6) Coal mine mobile shielded rubber sheathed flexible cable, rated voltage is 3.6/6KV, power core 3*25, ground core 1*16, for low temperature environment, with semi-conductive shielding layer, expressed as: MYDP-3.6/6 3*25+1*16 MT818.7-1999


7) Coal mine electric drill shielded elastomer cable, rated voltage 0.3/0.5KV, power core 3*4, ground core 1*4, expressed as: MZPE-0.3/0.53*4+1*4 MT818.8-1999


8) Mobile light rubber sheathed flexible cable for coal mine, rated voltage 0.3/0.5KV, insulated core 3*2.5, without shielding layer, expressed as: MYQ-0.3/0.5 3*2.5 MT818.9-1999


9) Miner's hat lamp wire for coal mine, insulated core 2*0.75, expressed as: MM 2*0.75MT818.10-1999


Note: The above model of mining cable means the stipulation in MT818, according to the national standard GB12972, the serial code is U, which is the second letter of the pinyin of the mine word, because the first letter K has been occupied by the control cable, and the rest The codes are basically the same.